dc.description.abstractAim: To compare biochemical clearances with extended-hours haemodialysis (HD) and haemodiafiltration (HDF) and Fresenius FX80 (FX) and Nipro Elisio (NE) dialysers. Background(s): Extended-hours HD has long been regarded as the optimal form of dialysis for solute clearance. With emerging benefits of HDF, it would be prudent to compare these two head-to-head. Method(s): This is a randomized cross-over trial comparing 8-hours HD to 4-hours HDF. 12 NHD patients underwent a baseline 8-hour HD session, and then randomized to either 2 weeks of 8-hour HD or 4-hour HDF with crossover to the alternative treatment after a 2-week washout period. Subjects were additionally randomized to the NE or FX dialyser in a parallel design. Blood and dialysate samples were collected at baseline and at the end of both study periods. Result(s): Mean (SD) age and BMI were 55.1 +/-11.5 years and 36.4 +/-10.8 respectively. Blood flow (Qb) for HD was 250ml/min and dialysate flow (Qd) 300ml/min. For HDF, Qb was 300ml/min and Qd 500ml/min with mean convection rate 86.1ml/min (20.7 L/session). Urea and creatinine reduction ratios were higher with HD compared to HDF (difference 14.0%, 95% CI 10.6,17.3, p<0.001 & 9.1% 95% CI 11.0,7.2, p<0.001). Fibroblast growth factor 23 (FGF23) clearance was superior with HDF (difference 20.1%, 95% CI 8.7,31.6, p=0.001). No difference was seen in reduction ratios for phosphate, retinol binding protein, alpha-1-microglobulin, beta-2-microglobulin (B2M) and fetuin with both modalities. Compared to NE, FX dialyser achieved higher beta-2-microglobulin clearance (Period 1: difference 7.8%, 95% CI 1.3, 14.4, P=0.02, Period 2: 7.5%, 95%CI 1.0, 14.1, p=0.02). Conclusion(s): Small solute clearance was superior with extended-hours HD while HDF enhanced FGF23 clearance. B2M clearance was improved with Fresenius FX80 dialyser.en
dc.languageEnglishen
dc.languageenen
dc.publisherBlackwell Publishingen
dc.titleBiochemical comparison of 8-hour haemodialysis and 4-hour haemodiafiltration, and two dialysis membranes.en
dc.typeConference Abstracten
dc.identifier.affiliationNephrologyen
dc.type.studyortrialRandomised controlled trial-
dc.identifier.doihttp://monash.idm.oclc.org/login?url=http://dx.doi.org/10.1111/nep.13103en
local.date.conferencestart2017-09-04en
dc.identifier.source618236224en
dc.identifier.institution(Choo, Polkinghorne, Kerr) Department of Nephrology, Monash Health, Clayton, VIC, Australia (Polkinghorne, Kerr) Monash University, Clayton, VIC, Australiaen
dc.description.addressS.Z. Choo, Department of Nephrology, Monash Health, Clayton, VIC, Australiaen
dc.description.publicationstatusCONFERENCE ABSTRACTen
local.date.conferenceend2017-09-06en
dc.rights.statementCopyright 2017 Elsevier B.V., All rights reserved.en
dc.identifier.affiliationext(Polkinghorne, Kerr) Monash University, Clayton, VIC, Australia-
dc.identifier.affiliationmh(Choo, Polkinghorne, Kerr) Department of Nephrology, Monash Health, Clayton, VIC, Australia-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.grantfulltextnone-
item.fulltextNo Fulltext-
item.openairetypeConference Abstract-
crisitem.author.deptNephrology-
crisitem.author.deptNephrology-
Appears in Collections:Conferences
Show simple item record

Page view(s)

22
checked on Sep 13, 2024

Google ScholarTM

Check


Items in Monash Health Research Repository are protected by copyright, with all rights reserved, unless otherwise indicated.