Please use this identifier to cite or link to this item:
https://repository.monashhealth.org/monashhealthjspui/handle/1/50125
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Goel V. | - |
dc.contributor.author | Cameron W. | - |
dc.contributor.author | Spear E. | - |
dc.contributor.author | Sultana N. | - |
dc.contributor.author | Chan J. | - |
dc.contributor.author | Cheen Y.C. | - |
dc.contributor.author | Tan S. | - |
dc.contributor.author | Tan C. | - |
dc.contributor.author | Mantey R. | - |
dc.contributor.author | Brown A. | - |
dc.contributor.author | Nerlekar N. | - |
dc.date.accessioned | 2023-08-24T05:21:43Z | - |
dc.date.available | 2023-08-24T05:21:43Z | - |
dc.date.copyright | 2023 | - |
dc.date.issued | 2023-08-04 | en |
dc.identifier.citation | Heart Lung and Circulation. Conference: 71st Annual Scientific Meeting of the Cardiac Society of Australia and New Zealand. Adelaide Australia. 32(Supplement 3) (pp S383), 2023. Date of Publication: July 2023. | - |
dc.identifier.uri | https://repository.monashhealth.org/monashhealthjspui/handle/1/50125 | - |
dc.description.abstract | Background: Mammographically detected breast arterial calcification (BAC) is a risk marker for cardiovascular disease, but not routinely reported. With the advent of artificial intelligence (AI) in medical imaging: automated, quantitative BAC assessment may facilitate seamless integration into clinical workflow and allow personalised risk assessment. We conducted external validation of a novel AI software designed to quantify mammographic BAC. Method(s): We obtained full-field digital mammograms from 285 women. BAC was evaluated as present/absent by two experienced mammographers with discordance adjudicated by third observer. AI algorithm (cmAngio, CureMetrix, USA) produced a quantitative BAC score (scale 0-100) based on area, extent and intensity, internally validated on 17,000 accessions. Agreement measured by kappa-coefficient, and diagnostic performance by area under the curve (AUC). Result(s): A total of 1,232 images were evaluated with excellent interobserver agreement (kappa 0.96, p<0.001). The visual prevalence of BAC was 30% and 55% with AI software. Algorithm performance was excellent (AUC 0.91, 0.87-0.95) compared to human identification (Figure). Discordant cases (algorithm positive, human negative) all demonstrated low BAC scores (<26), which may suggest limitation of human detection for faint BAC. Sensitivity, specificity, positive and negative predictive value was 92%, 61%, 51%, 95% respectively. Average image analysis time was 34 seconds for humans and 2.5 seconds for software. Conclusion(s): Our results demonstrate high diagnostic performance of rapid AI-based BAC detection software, that additionally provides quantitative scoring and capable of detecting fainter lesions. Automated BAC detection may offer an efficient and superior method than human identification without impacting clinical workflow for radiologists. Further study to assess this impact on cardiac risk prediction is needed. [Formula presented]Copyright © 2023 | - |
dc.publisher | Elsevier Ltd | - |
dc.relation.ispartof | Heart Lung and Circulation | - |
dc.subject.mesh | artery calcification | - |
dc.subject.mesh | artificial intelligence | - |
dc.subject.mesh | breast | - |
dc.subject.mesh | heart | - |
dc.subject.mesh | image analysis | - |
dc.subject.mesh | mammography | - |
dc.subject.mesh | radiologist | - |
dc.title | Artificial Intelligence Software Demonstrates High Performance for Breast Arterial Calcification Detection on Mammography. | - |
dc.type | Conference Abstract | - |
dc.identifier.affiliation | Cardiology (MonashHeart) | - |
dc.description.conferencename | 71st Annual Scientific Meeting of the Cardiac Society of Australia and New Zealand | - |
dc.description.conferencelocation | Adelaide, Australia | - |
dc.identifier.doi | http://monash.idm.oclc.org/login?url=https://dx.doi.org/10.1016/j.hlc.2023.06.504 | - |
local.date.conferencestart | 2023-08-03 | - |
dc.identifier.institution | (Goel, Cameron, Spear, Sultana, Chan, Cheen, Tan, Brown, Nerlekar) Monash Health, Melbourne, Vic, Australia | - |
dc.identifier.institution | (Chan, Cheen, Tan, Brown, Nerlekar) Victorian Heart Institute, Melbourne, Vic, Australia | - |
dc.identifier.institution | (Chan, Brown, Nerlekar) Baker Heart and Diabetes Institute, Melbourne, Vic, Australia | - |
dc.identifier.institution | (Mantey, Nerlekar) CureMetrix, San Diego, CA, United States | - |
dc.identifier.institution | (Tan) FMIG, Melbourne, Vic, Australia | - |
local.date.conferenceend | 2023-08-06 | - |
dc.identifier.affiliationmh | (Goel, Cameron, Spear, Sultana, Chan, Cheen, Tan, Brown, Nerlekar) Monash Health, Melbourne, Vic, Australia | - |
item.fulltext | No Fulltext | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.grantfulltext | none | - |
item.openairetype | Conference Abstract | - |
item.cerifentitytype | Publications | - |
crisitem.author.dept | Cardiology (MonashHeart & Victorian Heart Institute) | - |
crisitem.author.dept | Cardiology (MonashHeart & Victorian Heart Institute) | - |
Appears in Collections: | Conferences |
Items in Monash Health Research Repository are protected by copyright, with all rights reserved, unless otherwise indicated.