Please use this identifier to cite or link to this item: https://repository.monashhealth.org/monashhealthjspui/handle/1/50653
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBawazeer O.-
dc.contributor.authorFallatah A.-
dc.contributor.authorAlasmary M.-
dc.contributor.authorBokhary Y.-
dc.contributor.authorAlmerabi A.-
dc.contributor.authorKhan S.-
dc.contributor.authorAbuhadi N.-
dc.contributor.authorAlalawi A.-
dc.contributor.authorAsiri N.-
dc.contributor.authorBawazir S.-
dc.contributor.authorAl-Qahtani S.-
dc.contributor.authorAlgethami M.-
dc.contributor.authorBadawy M.-
dc.date.accessioned2023-12-28T04:55:12Z-
dc.date.available2023-12-28T04:55:12Z-
dc.date.copyright2023-
dc.date.issued2023-12-02en
dc.identifier.citationEgyptian Journal of Radiology and Nuclear Medicine. 54(1) (no pagination), 2023. Article Number: 203. Date of Publication: December 2023.-
dc.identifier.urihttps://repository.monashhealth.org/monashhealthjspui/handle/1/50653-
dc.description.abstractBackground: Radiation shielding in radiology has historically been achieved with lead; however, there has been an increasing demand for radiation shielding to be more environmentally friendly. Barium has shown promise as a substitute in many radiology applications. This study aims to investigate a barium sulphate shield in protecting the thyroid and the eye lens during panoramic radiography. Method(s): During a simulated panoramic examination, an anthropomorphic phantom and a solid-state detector measured the radiation dose to the surface thyroid and the eye lens. The measurements were taken using no shield and a barium sulphate shield. A Welch's T-test was employed to compute the shield's effect on radiation. Two radiologists assessed the image quality with and without the thyroid shields. Result(s): The dose reduction was between 66 and 75% for the barium shield at the thyroid. The dose reduction ranged between 15 and 61% in the eye region. Images using a barium shield were deemed adequate for diagnostic interpretation. Conclusion(s): Barium shields effectively reduce the radiation dose in the thyroid region during panoramic radiography without degrading image quality. The dose reduction depends on the tube voltage and the area of interest.Copyright © 2023, The Author(s).-
dc.publisherInstitute for Ionics-
dc.relation.ispartofEgyptian Journal of Radiology and Nuclear Medicine-
dc.subject.meshionizing radiation-
dc.subject.meshpanoramic radiography-
dc.subject.meshradiation dose-
dc.subject.meshradiation safety-
dc.subject.meshradiation shield-
dc.subject.meshradiologist-
dc.subject.meshbarium-
dc.titleInvestigation of barium sulphate shielding during panoramic radiography.-
dc.typeArticle-
dc.identifier.affiliationRadiology-
dc.identifier.doihttp://monash.idm.oclc.org/login?url=https://dx.doi.org/10.1186/s43055-023-01157-z-
dc.publisher.placeGermany-
dc.identifier.institution(Bawazeer, Khan, Alalawi, Al-Qahtani) Physics Department, Umm Al-Qura University, Makkah, Saudi Arabia-
dc.identifier.institution(Fallatah, Alasmary, Bokhary) Medical Physics Department, King Fahad General Hospital, Jeddah, Saudi Arabia-
dc.identifier.institution(Almerabi) Diagnostic Radiology Department, King Fahad General Hospital, Jeddah, Saudi Arabia-
dc.identifier.institution(Abuhadi) Diagnostic Radiology Department, Applied Medical Sciences College, Jazan University, Jazan, Saudi Arabia-
dc.identifier.institution(Asiri) Diagnostic Radiology Department, King Abdullah Medical Complex, Jeddah, Saudi Arabia-
dc.identifier.institution(Bawazir) Dental Department, My Dental Clinic, Jeddah, Saudi Arabia-
dc.identifier.institution(Algethami) Physics Department, Faculty of Science, Taif University, Taif, Saudi Arabia-
dc.identifier.institution(Badawy) Monash Health Imaging, Monash Health, Clayton, VIC, Australia-
dc.identifier.institution(Badawy) Department of Medical Imaging and Radiation Sciences, Faculty of Medicine, Monash University, Clayton, Australia-
dc.identifier.affiliationmh(Badawy) Monash Health Imaging, Monash Health, Clayton, VIC, Australia-
item.grantfulltextnone-
item.fulltextNo Fulltext-
item.openairetypeArticle-
item.cerifentitytypePublications-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
crisitem.author.deptRadiology-
Appears in Collections:Articles
Show simple item record

Page view(s)

32
checked on Jan 18, 2025

Google ScholarTM

Check


Items in Monash Health Research Repository are protected by copyright, with all rights reserved, unless otherwise indicated.