Please use this identifier to cite or link to this item: https://repository.monashhealth.org/monashhealthjspui/handle/1/37096
Full metadata record
DC FieldValueLanguage
dc.contributor.authorVerma K.P.en
dc.contributor.authorAdam D.en
dc.date.accessioned2021-05-14T12:36:28Zen
dc.date.available2021-05-14T12:36:28Zen
dc.date.copyright2018en
dc.date.created20181011en
dc.date.issued2018-10-11en
dc.identifier.citationPACE - Pacing and Clinical Electrophysiology. 41 (10) (pp 1381-1383), 2018. Date of Publication: October 2018.en
dc.identifier.issn0147-8389en
dc.identifier.urihttps://repository.monashhealth.org/monashhealthjspui/handle/1/37096en
dc.description.abstractA 62-year-old male presented to his treating cardiologist for routine interrogation of his implantable cardiac defibrillator on the background of severe ischemic cardiomyopathy and end-stage kidney disease on hemodialysis. The device log revealed multiple paroxysms of atrial fibrillation; however, upon scrutinizing these episodes it was evident that they always corresponded to episodes of hemodialysis while dialyzing through a chronic dialysis catheter, but not while dialyzing via an arteriovenous fistula. We report the novel finding of inappropriate sensing of current leak from the catheter by a lead with a floating atrial dipole.Copyright © 2018 Wiley Periodicals, Inc.en
dc.languageenen
dc.languageEnglishen
dc.publisherBlackwell Publishing Inc. (E-mail: subscrip@blackwellpub.com)en
dc.relation.ispartofPACE - Pacing and Clinical Electrophysiologyen
dc.titleAn unusual source of electromagnetic interference.en
dc.typeArticleen
dc.type.studyortrialCase series or case report-
dc.identifier.doihttp://monash.idm.oclc.org/login?url=http://dx.doi.org/10.1111/pace.13418en
dc.publisher.placeUnited Statesen
dc.identifier.orcidVerma, Kunal Pradip; ORCID: http://orcid.org/0000-0002-0712-1011en
dc.identifier.pubmedid29924894 [http://www.ncbi.nlm.nih.gov/pubmed/?term=29924894]en
dc.identifier.source623336561en
dc.identifier.institution(Verma, Adam) Monash Heart, Monash Health, VIC, Australiaen
dc.description.addressK.P. Verma, Monash Heart, Monash Health, VIC, Australia. E-mail: kpverma20@gmail.comen
dc.description.publicationstatusEmbaseen
dc.rights.statementCopyright 2019 Elsevier B.V., All rights reserved.en
dc.subect.keywordsatrial dipole electromagnetic interference hemodialysisen
dc.identifier.authoremailVerma K.P.; kpverma20@gmail.comen
item.fulltextNo Fulltext-
item.cerifentitytypePublications-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.grantfulltextnone-
item.openairetypeArticle-
crisitem.author.deptCardiology (MonashHeart & Victorian Heart Institute)-
Appears in Collections:Articles
Show simple item record

Page view(s)

32
checked on Feb 6, 2025

Google ScholarTM

Check


Items in Monash Health Research Repository are protected by copyright, with all rights reserved, unless otherwise indicated.