Title: Modified tightening for figure-of-eight sternal wiring closure.
Authors: Chakaramakkill M.J.;Ratinam R. ;Bhagwat K.A.;Stephens G.C.
Institution: (Bhagwat, Stephens) Department of Cardiothoracic Surgery, Alfred Health, 55 Commercial Rd, Melbourne, VIC 3181, Australia (Chakaramakkill) National Heart Centre, Singapore, Singapore (Ratinam) Department of Surgery, Monash Medical Centre, Melbourne, Australia
Issue Date: 12-Nov-2015
Copyright year: 2015
Publisher: Lippincott Williams and Wilkins (E-mail: agents@lww.com)
Place of publication: United Kingdom
Publication information: Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery. 10 (5) (pp 368-369), 2015. Date of Publication: 2015.
Journal: Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery
Abstract: This is a simple and quick method for the tightening of figure-of-eight wires routinely used for sternal closure. This technique gives a stable approximation, adequate reduction, and immobilization, providing higher strength and rigidity compared with conventional figure-of-eight closure. The advantage of this technique is that it tightens all the four wires equally, thus avoiding loose loops.Copyright © 2015 by the International Society for Minimally Invasive Cardiothoracic Surgery.
DOI: http://monash.idm.oclc.org/login?url=http://dx.doi.org/10.1097/IMI.0000000000000194
ISSN: 1556-9845
URI: https://repository.monashhealth.org/monashhealthjspui/handle/1/41091
Type: Article
Appears in Collections:Articles

Show full item record

Page view(s)

50
checked on Sep 25, 2025

Google ScholarTM

Check


Items in Monash Health Research Repository are protected by copyright, with all rights reserved, unless otherwise indicated.