Please use this identifier to cite or link to this item: https://repository.monashhealth.org/monashhealthjspui/handle/1/42514
Title: A survey of central venous catheter practices in Australian and New Zealand tertiary neonatal units.
Authors: Tan K. ;Taylor J.E.;McDonald S.J.
Monash Health Department(s): Social Work
Physiotherapy
Allied Health
Institution: (Taylor) La Trobe University, Bundoora, Australia; Monash Newborn, Monash Medical Centre, Clayton, Australia. Electronic address: jacquie.taylor@monashhealth.org (McDonald) La Trobe University, Bundoora, Australia; Midwifery Professorial Unit, Mercy Hospital for Women, Melbourne, Australia (Tan) Monash Newborn, Monash Medical Centre, Clayton, Australia; Monash Institute of Medical Research, Monash University, Clayton, Australia
Issue Date: 13-Apr-2015
Copyright year: 2014
Place of publication: Australia
Publication information: Australian critical care : official journal of the Confederation of Australian Critical Care Nurses. 27 (1) (pp 36-42), 2014. Date of Publication: 01 Feb 2014.
Abstract: BACKGROUND: Infection is the most common problem with central venous catheters (CVCs) in neonates. There are two published guidelines, including the Centers for Disease Control and Prevention (CDC), for the prevention of intravascular catheter-related infection that describes evidence-based practice to reduce nosocomial infection. OBJECTIVE: Our aims were to survey current medical and nursing management of central venous catheters in tertiary neonatal intensive care units in Australia and New Zealand and to compare with the CDC evidence-based practice guideline. METHODS: A cross sectional survey was performed across 27 Australian and New Zealand neonatal units in September 2012. Two web-based questionnaires were distributed, one to medical directors related to the insertion of CVCs while CVC "maintenance" surveys were sent to nurse unit managers. RESULTS: Seventy percent (19/27) medical management and 59% (16/27) on nursing management surveys were completed. In all neonatal intensive care units (NICUs) there were guidelines for CVC maintenance and for 18 out of 19 there were guidelines for insertion. In the seven units using femoral lines, three had a guideline on insertion and four for maintenance. CVC insertion was restricted to credentialed staff in 57.9% of neonatal units. Only 26.5% used full maximal sterile barriers for insertion. Skin disinfection practices widely varied. Dressing use and dressing change regimens were standardised; all using a semi-permeable dressing. Duration of cleaning time of the access point varied significantly; however, the majority used a chlorhexidine with alcohol solution (68.8%). Line and fluid changes varied from daily to 96 h. The majority used sterile gloves and a sterile dressing pack to access the CVC (68.8%). In the majority of NICUs stopcocks were used (62.5%) with a needle-less access point attached (87.5%). In less than 50% of NICUs education was provided on insertion and maintenance. CONCLUSION: There is diversity of current practices and some aspects vary from the CDC guideline. There is a need to review NICU current practices to align with evidence based guidelines. The introduction of a common guideline may reduce variations in practice.Copyright © 2013 Australian College of Critical Care Nurses Ltd. Published by Elsevier Ltd. All rights reserved.
DOI: http://monash.idm.oclc.org/login?url=http://dx.doi.org/10.1016/j.aucc.2013.11.002
PubMed URL: 24315154 [http://www.ncbi.nlm.nih.gov/pubmed/?term=24315154]
ISSN: 1036-7314
URI: https://repository.monashhealth.org/monashhealthjspui/handle/1/42514
Type: Article
Type of Clinical Study or Trial: Observational study (cohort, case-control, cross sectional or survey)
Appears in Collections:Articles

Show full item record

Page view(s)

56
checked on Jan 5, 2025

Google ScholarTM

Check


Items in Monash Health Research Repository are protected by copyright, with all rights reserved, unless otherwise indicated.