Please use this identifier to cite or link to this item: https://repository.monashhealth.org/monashhealthjspui/handle/1/52641
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMartis W.R.-
dc.contributor.authorAllen C.-
dc.contributor.authorAhmed R.-
dc.contributor.authorIsmail H.-
dc.contributor.authorWoodford S.-
dc.contributor.authorRiedel B.-
dc.date.accessioned2024-11-22T03:36:54Z-
dc.date.available2024-11-22T03:36:54Z-
dc.date.copyright2024-
dc.date.issued2024-10-24en
dc.identifier.citationAnaesthesia and Intensive Care. 52(6) (pp 420-426), 2024. Date of Publication: November 2024.-
dc.identifier.urihttps://repository.monashhealth.org/monashhealthjspui/handle/1/52641-
dc.description.abstractLaparoscopic robot-assisted colorectal surgery can pose significant haemodynamic challenges for patients with severe aortic regurgitation. The increased afterload caused by pneumoperitoneum and aortic compression, along with concurrent factors like hypercarbia, Trendelenburg positioning and ventilatory impairment, can worsen aortic regurgitation, leading to myocardial ischaemia and heart failure. Transoesophageal echocardiography (TOE) assists haemodynamic management intraoperatively but requires subspecialist skills and enables limited inferences to be drawn regarding the impact of afterload on myocardial performance. Minimally invasive haemodynamic monitoring enabling real-time visualisation of a patient's 'pressure field' has been suggested as a potential adjunct or alternative to TOE, with the added advantage of providing continuous quantitative information about both stroke volume and the afterload to ventricular ejection in a single visualisation. We describe an example of successful concurrent use of pressure field haemodynamic monitoring and TOE in a patient with severe aortic regurgitation having a prolonged laparoscopic robot-assisted pelvic exenteration.Copyright © The Author(s) 2024.-
dc.publisherSAGE Publications Inc.-
dc.relation.ispartofAnaesthesia and Intensive Care-
dc.subject.meshaortic regurgitation-
dc.subject.meshechocardiography-
dc.subject.meshhemodynamic monitoring-
dc.subject.meshhemodynamics-
dc.subject.meshrobot assisted surgery-
dc.titleIntraoperative 'pressure field' haemodynamic monitoring in a patient with severe aortic regurgitation having laparoscopic robot-assisted colorectal surgery.-
dc.typeArticle-
dc.type.studyortrialReview article (e.g. literature review, narrative review)-
dc.identifier.doihttps://dx.doi.org/10.1177/0310057X241263115-
dc.publisher.placeAustralia-
dc.identifier.pubmedid39415740 [https://www.ncbi.nlm.nih.gov/pubmed/?term=39415740]-
dc.identifier.institution(Martis, Allen, Ahmed, Ismail, Riedel) Peter MacCallum Cancer Centre, Melbourne, Australia-
dc.identifier.institution(Martis) Monash Health, Melbourne, Australia-
dc.identifier.institution(Martis, Ismail, Woodford) Department of Critical Care, University of Melbourne, Australia-
dc.identifier.institution(Woodford) Austin Health, Melbourne, Australia-
dc.identifier.institution(Riedel) The Sir Peter MacCallum Department of Oncology, Department of Critical Care, University of Melbourne, Australia-
dc.identifier.affiliationmh(Martis) Monash Health, Melbourne, Australia-
item.openairetypeArticle-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextNo Fulltext-
item.grantfulltextnone-
item.cerifentitytypePublications-
Appears in Collections:Articles
Show simple item record

Page view(s)

22
checked on Jan 9, 2025

Google ScholarTM

Check


Items in Monash Health Research Repository are protected by copyright, with all rights reserved, unless otherwise indicated.