Please use this identifier to cite or link to this item: https://repository.monashhealth.org/monashhealthjspui/handle/1/52641
Title: Intraoperative 'pressure field' haemodynamic monitoring in a patient with severe aortic regurgitation having laparoscopic robot-assisted colorectal surgery.
Authors: Martis W.R.;Allen C.;Ahmed R.;Ismail H.;Woodford S.;Riedel B.
Institution: (Martis, Allen, Ahmed, Ismail, Riedel) Peter MacCallum Cancer Centre, Melbourne, Australia
(Martis) Monash Health, Melbourne, Australia
(Martis, Ismail, Woodford) Department of Critical Care, University of Melbourne, Australia
(Woodford) Austin Health, Melbourne, Australia
(Riedel) The Sir Peter MacCallum Department of Oncology, Department of Critical Care, University of Melbourne, Australia
Issue Date: 24-Oct-2024
Copyright year: 2024
Publisher: SAGE Publications Inc.
Place of publication: Australia
Publication information: Anaesthesia and Intensive Care. 52(6) (pp 420-426), 2024. Date of Publication: November 2024.
Journal: Anaesthesia and Intensive Care
Abstract: Laparoscopic robot-assisted colorectal surgery can pose significant haemodynamic challenges for patients with severe aortic regurgitation. The increased afterload caused by pneumoperitoneum and aortic compression, along with concurrent factors like hypercarbia, Trendelenburg positioning and ventilatory impairment, can worsen aortic regurgitation, leading to myocardial ischaemia and heart failure. Transoesophageal echocardiography (TOE) assists haemodynamic management intraoperatively but requires subspecialist skills and enables limited inferences to be drawn regarding the impact of afterload on myocardial performance. Minimally invasive haemodynamic monitoring enabling real-time visualisation of a patient's 'pressure field' has been suggested as a potential adjunct or alternative to TOE, with the added advantage of providing continuous quantitative information about both stroke volume and the afterload to ventricular ejection in a single visualisation. We describe an example of successful concurrent use of pressure field haemodynamic monitoring and TOE in a patient with severe aortic regurgitation having a prolonged laparoscopic robot-assisted pelvic exenteration.Copyright © The Author(s) 2024.
DOI: https://dx.doi.org/10.1177/0310057X241263115
PubMed URL: 39415740 [https://www.ncbi.nlm.nih.gov/pubmed/?term=39415740]
URI: https://repository.monashhealth.org/monashhealthjspui/handle/1/52641
Type: Article
Subjects: aortic regurgitation
echocardiography
hemodynamic monitoring
hemodynamics
robot assisted surgery
Type of Clinical Study or Trial: Review article (e.g. literature review, narrative review)
Appears in Collections:Articles

Show full item record

Page view(s)

22
checked on Jan 10, 2025

Google ScholarTM

Check


Items in Monash Health Research Repository are protected by copyright, with all rights reserved, unless otherwise indicated.