Please use this identifier to cite or link to this item: https://repository.monashhealth.org/monashhealthjspui/handle/1/57841
Title: Contamination Associated With Glove Changing Techniques in the Operating Theatre
Authors: Boekel P.;EK E.T. 
Monash Health Department(s): Orthopaedic Surgery
Institution: (Ek) Department of Orthopaedic Surgery, Monash Health, Melbourne, Victoria, Australia
Issue Date: 22-Mar-2022
Copyright year: 2022
Place of publication: United States
Publication information: Font Surg. Mar 22(9), (839040). Date of publication: 22 Mar, 2022.
Journal: Frontiers in Surgery
Abstract: Background: Sterility of the operative field during surgery is imperative in reducing the risk of infection. Most commonly, double gloves are worn by surgeons. When contamination occurs, the top gloves are changed intra-operatively. No studies have investigated which glove changing technique is best. Therefore, in this study, we aim to identify which top glove changing technique causes the least surface contamination. Methods: Glitterbug™ (UV fluorescent powder) was applied to the top gloves of 3 individuals who changed their top gloves according to a randomised method - Method 1: 3 pairs worn, remove the outer pair; Method 2: 2 pairs worn, remove the top glove, replace unassisted; and Method 3: 2 pairs worn, remove the top glove, and replace assisted by a scrub nurse. A blinded investigator inspected for Glitterbug™ contamination under UV light. Results: Two hundred and ten trials were performed and two types of contamination were identified, namely, direct contact and airborne spread. For absolute contamination, Method 1 had 59/64 (92%) contaminated trials, Method 2 had 49/65 (75%) contaminated trials, and Method 3 had 64/81 (79%) contaminated trials. This was statistically significant (p = 0.031). For direct contamination only, Method 1 had 38/64 (59%) contaminated trials, Method 2 had 24/65 (37%) contaminated trials, and Method 3 had 20/81 (25%) contaminated trials. This was statistically significant (p < 0.0001). Conclusions: Method 2 had a statistically significant lower contamination rate overall, with Method 3 having the lowest direct contamination rate. We believe that wearing 2 gloves, removing the top glove and replacing it, either assisted or unassisted, could decrease surface contamination of the sterile field.
DOI: http://monash.idm.oclc.org/login?url=https://doi.org/10.3389/fsurg.2022.839040
PubMed URL: 35392064
URI: https://repository.monashhealth.org/monashhealthjspui/handle/1/57841
Type: Article
Subjects: orthopaedic surgery
healthcare-associated infection
infection prevention
personal protective equipment
sterile field
surgery
surgical site infection
Appears in Collections:Articles