Please use this identifier to cite or link to this item:
https://repository.monashhealth.org/monashhealthjspui/handle/1/62360| Title: | The relationship between umbilical arterial pH, newborn heart rate and ventilation at birth - a prospective observational study. | Authors: | Rettedal S.;Buskov F.;Kibsgaard A.;Kvaloy J.T.;Hooper S.;Davis P.;Ersdal H.L. | Monash Health Department(s): | Monash University - School of Clinical Sciences at Monash Health Hudson Institute - The Ritchie Centre |
Institution: | (Rettedal, Buskov, Kibsgaard, Ersdal) Department of Simulation-based Learning, Stavanger University Hospital, Stavanger, Norway (Rettedal, Buskov, Ersdal) Faculty of Health Sciences, University of Stavanger, Stavanger, Norway (Kvaloy) Department of Research, Section of Biostatistics, Stavanger University Hospital, Stavanger, Norway (Kvaloy) Department of Mathematics and Physics, University of Stavanger, Stavanger, Norway (Hooper) Department of Obstetrics, and Gynaecology, Monash University, Melbourne, Australia (Hooper) The Ritchie Centre, Hudson Institute for Medical Research, Melbourne, Australia (Davis) Department of Obstetrics, Gynaecology and Newborn Health, University of Melbourne, Australia (Davis) The Royal Women's Hospital, Melbourne, Australia |
Issue Date: | 20-Oct-2026 | Copyright year: | 2026 | Publisher: | Elsevier Ireland Ltd | Place of publication: | Ireland | Publication information: | Resuscitation. 227(no pagination), 2026. Article Number: 111197. Date of Publication: 01 Oct 2026. | Journal: | Resuscitation | Abstract: | Objective: To investigate the relationship between umbilical arterial pH (UA-pH), heart rate (HR) and positive pressure ventilation (PPV) at birth. Method(s): A prospective cohort study conducted at Stavanger University Hospital, Norway, June 2019-November 2021. Newborns of gestational age >=28 weeks were eligible for inclusion. UA-pH was routinely obtained at birth and newborn HR captured using dry-electrode ECG. Relationships were evaluated using linear correlation and logistic regression. UA-pH was categorised as <7.00, 7.00-7.09, 7.10-7.19, with reference group 7.20-7.50. Outcome measures were newborn HR and PPV. Result(s): Among 3662 newborns the median (quartiles) UA-pH was 7.24 (7.19, 7.29). UA-pH <7.00 was identified in 20 (0.5%), 7.00-7.09 in 140 (3.8%), 7.10-7.19 in 833 (23%), and 7.20-7.50 in 2669 (73%) newborns. There was a weak and clinically insignificant linear correlation between UA-pH and first measured HR at 16 (11, 30) s (r = 0.07, p < 0.001), and no linear correlation with HR at one minute (r = -0.03, p = 0.07). Even among newborns with UA-pH <7.00, only 50% were bradycardic with HR values <100 bpm in the first minute (OR 5.0 (1.9, 12.9), p < 0.001). PPV was provided to 117/3662 (3.2%) of newborns. One-third with UA-pH <7.00 received PPV at birth (OR 21.9 (8.0, 55.4), p < 0.001). Apgar scores were strongly associated with UA-pH. Conclusion(s): There was no linear correlation between UA-pH and HR at one minute. Although HR alone was not a good indicator of acidaemia, low UA-pH is associated with bradycardia and PPV. Apgar scores reflected the degree of birth asphyxia very well. Clinical Trial Registration: NCT03849781.Copyright © 2026 The Author(s) | DOI: | http://monash.idm.oclc.org/login?url=10.1016/j.resuscitation.2026.111197 | PubMed URL: | 42413757 | URI: | https://repository.monashhealth.org/monashhealthjspui/handle/1/62360 | Type: | Article | Subjects: | Apgar score arterial pH electrocardiogram gestational age heart rate hospital admission neonatal intensive care unit newborn Norway perinatal asphyxia positive pressure ventilation umbilical artery university hospital electrocardiograph |
Type of Clinical Study or Trial: | Observational study |
| Appears in Collections: | Articles |
Show full item record
Items in Monash Health Research Repository are protected by copyright, with all rights reserved, unless otherwise indicated.
